ASPYRE® AT
Modular and Scalable Power Controllers Enable Increased Throughput and Yield While Reducing System Complexity
The ASPYRE® AT is a family of flexible, compact and scalable smart SCR power controllers. It features multiple advanced firing and control mode algorithms combined with sophisticated diagnostics. The ASPYRE AT integrates easily with EZ-ZONE® RM, PM PLUS® and RMA PLUS™ controllers as part of a Watlow® ecosystem solution.
Specifications
Power Bases
- Single-phase, 1 controlled leg
Load Amp Range
- 12A, 24A and 48A options (see derating curves)
SCR and Amperage Rating
- SCCR rating 100,000A up to 480VAC with coordinated fusing
- SCCR rating 10,000A up to 240VAC with recommended circuit breaker
- Power dissipation: Approximately 1 to 1.2 watts per amp
- Leakage current: 1mA at 25°C
Line and Load Voltage Range
- 100 to 480V
Voltage Frequency
- Automatically compensates for 47 to 63Hz
Controller Operating Supply Voltage
- 24VDC, 6W 6VA per ASPYRE AT unit
- Maximum 10 units powered via terminal screw and backplane connector
- Use split-rail configuration when more units are required
Voltage and Current Measurement Accuracy
- ±2% of range
Control Modes
- Voltage, voltage squared, current, current squared, power
Output Control Firing Types
- Fixed time-base zero crossing
- Variable time-base zero crossing (burst firing)
- Phase angle
Digital Inputs and Outputs
- Independently user-configurable as input or switched DC output
- Update rate: 10Hz
- Input type: User-selectable, dc voltage or dry contact
- Input logic: On ≥ 4VDC, off ≤ 1VDC, 30VDC max
- Output voltage: 24V (based on the supply voltage)
- Output: 100mADC max. per channel
Analog Input
- Voltage: 0-10VDC, 15kΩ impedance
- Current: 4 to 20mA, 0 to 20mADC, 100Ω impedance
Analog Output
- 0 to 20mADC ±120μA or 4 to 20mADC into 500Ω max. load
with 30μA nominal resolution - 0 to 10VDC ±60mV into a 500Ω min. load with 15mV
nominal resolution
Electromechanical Relay Output
- Form C, 5A resistive load
- 100,000 cycles at 24VDC, 120/240 VAC
- 125VA pilot duty 120/240VAC
- 25VA 24VAC/DC
Connectivity
- EIA 485, Modbus® RTU (option)
- USB device
- EtherCAT® ETG (future option)
- Modbus® TCP (future option)
- EtherNet/IP™ (future option)
- ProfiNet (future option)
Diagnostics
- Open load circuit (including heater break) partial load failure, SCR short circuit, current limit, thermal alarm, line voltage loss
Operator Interface
- 4 discrete LED indicators for status monitoring
COMPOSER® PC Configuration Software
- Connects via USB port
- Easy-to-use test drive screen
- Function block diagram programming
Cooling Options
- DIN-rail heat sink for convection cooling
- Base plate for use with customer supplied heat sink
Control Terminals
- Terminal blocks are touch safe, removable, 22 to 12 AWG, 5 in.-lb. (0.6 Nm) torque, 1/8 in. (3.5 mm) flat blade screw driver
Line and Load Terminals
- Compatible with crimp lug terminals or bare wire, 12 to 6 AWG, 24 in.-lb. (2.7 Nm) torque, 1/8 in. hex driver
Ground Terminal
- Recommended 14 to 10 AWG with UL® Listed (ZMVV) #8 ring or spade crimp lug, 15 to 17 in.-lb (1.7 to 1.9 Nm) torque, , 1/4 in. (6.5 mm) flat blade screw driver
Mounting
- Panel mounting with screws or DIN rail
- No. 8 (M4) fastener
- DIN rail: 35mm x 7.5mm
Environment
- 0 to 60°C (single unit) or 55°C (multiple units) see derating curves
- 5 to 90% RH (relative humidity), non-condensing
Agency Approval and Regulatory
- UL® 508 Listed
- c-UL® Listed
- CE EMC Directive Class A Emissions
- CE Safety Directive EN 60947-4-3
- IP20
- RoHS 2015-863-EU
- W.E.E.E 2012-19-EU
- Enclosure Flammability Rating: 94-V0